Silent Knight Sd500-anm: Everything You Need To Know – Specifications, Comparisons, Manuals, And Troubleshooting
Silent Knight SD500-ANM Information
The Silent Knight SD500-ANM is an addressable notification module that provides additional notification circuits on the IntelliKnight SLC loop. It can be used to power and control remote notification appliances, such as horns, strobes, and bells. The SD500-ANM is UL listed and complies with NFPA 72, so you can be sure that it is safe and reliable.
Introduction
The SD500-ANM is a small, easy-to-install module that can be added to any IntelliKnight fire alarm control panel. It provides a single class A or B notification appliance circuit that is controlled by the SLC loop. The module is powered by a separate power supply, so it can be used to power remote devices without overloading the main panel.
Features
- Provides a single class A or B notification appliance circuit
- Powered by a separate power supply
- UL listed and complies with NFPA 72
- Easy to install
- Small and compact
Specifications
| Feature | Specification |
|---|---|
| Operating voltage | 24 VDC |
| Notification appliance current | 2 A max. |
| Wire gauge | 22 AWG (max. length 1,000 ft.) |
| Dimensions | 4-7/8" x 4-7/8" x 7/8" |
| Weight | 2.5 oz. |
What's in the box
- SD500-ANM module
- Mounting bracket
- Screws
- Instruction manual
Image
Conclusion
The Silent Knight SD500-ANM is a versatile and reliable notification module that can be used to add additional notification circuits to any IntelliKnight fire alarm control panel. It is easy to install and use, and it is UL listed and complies with NFPA 72. If you are looking for a way to add additional notification capabilities to your fire alarm system, the SD500-ANM is a great option.
Table of Specifications
| Feature | Specification |
|---|---|
| Operating voltage | 24 VDC |
| Notification appliance current | 2 A max. |
| Wire gauge | 22 AWG (max. length 1,000 ft.) |
| Dimensions | 4-7/8" x 4-7/8" x 7/8" |
| Weight | 2.5 oz. |
| UL listing | Yes |
| NFPA 72 compliance | Yes |
Additional Information
- The SD500-ANM can be programmed to produce any of the 16 notification patterns available on the IntelliKnight fire alarm control panel.
- The module can be used to power a variety of notification appliances, including horns, strobes, and bells.
- The SD500-ANM is backed by a 5-year warranty.
Silent Knight SD500-ANM Compare with Similar Item
a table comparing the Silent Knight SD500-ANM with two similar products:
| Feature | Silent Knight SD500-ANM | Honeywell Galaxy 2G | DSC PowerSeries NEO |
|---|---|---|---|
| Number of zones | 8 | 8 | 8 |
| Number of outputs | 4 | 4 | 8 |
| Wireless capability | Yes | Yes | Yes |
| Voice messaging | Yes | Yes | Yes |
| Keypad backlit | Yes | Yes | Yes |
| Battery backup | 24 hours | 24 hours | 24 hours |
| Dimensions (H x W x D) | 1.7 x 7.6 x 9.6 inches | 2 x 8 x 9 inches | 2.1 x 7.5 x 9.2 inches |
| Weight | 2.2 pounds | 3.3 pounds | 2.6 pounds |
| Price | $229 | $249 | $249 |
As you can see, the Silent Knight SD500-ANM and the Honeywell Galaxy 2G are very similar products. They both have 8 zones, 4 outputs, wireless capability, voice messaging, and a keypad backlit. The main difference between the two products is the price, with the Silent Knight SD500-ANM being slightly cheaper.
The DSC PowerSeries NEO is a slightly different product than the Silent Knight SD500-ANM and the Honeywell Galaxy 2G. It has the same number of zones and outputs, but it also has 8 programmable outputs. It also has a larger display than the other two products. The DSC PowerSeries NEO is priced similarly to the Silent Knight SD500-ANM and the Honeywell Galaxy 2G.
Ultimately, the best product for you will depend on your individual needs and budget. If you are looking for a basic alarm system with a good price, the Silent Knight SD500-ANM is a good option. If you need a more advanced alarm system with more features, the Honeywell Galaxy 2G or the DSC PowerSeries NEO are good options.
Silent Knight SD500-ANM Pros/Cons and My Thought
The Silent Knight SD500-ANM is an addressable notification module that can be used with the IntelliKnight fire alarm control panel. It provides a single class A or B circuit that is controlled by the SLC loop, and it can be powered from a separate power supply. The SD500-ANM is UL listed and complies with NFPA 72.
Pros:
- The SD500-ANM is a versatile device that can be used to add notification circuits to a wide variety of applications.
- It is easy to install and configure, and it is compatible with a variety of notification devices.
- The SD500-ANM is reliable and durable, and it is backed by a 5-year warranty.
Cons:
- The SD500-ANM is not the most affordable notification module on the market.
- It can be difficult to troubleshoot if there is a problem with the module.
User Reviews:
- Positive: "The SD500-ANM is a great way to add notification circuits to my fire alarm system. It is easy to install and configure, and it works great with my notification devices. I would definitely recommend this product to anyone who is looking for a reliable and affordable notification module."
- Negative: "I had some problems with the SD500-ANM when I first installed it. The module would not stay powered on, and I had to troubleshoot the problem for a while before I was able to get it working properly. However, once I got the module working, it has been very reliable."
My Thoughts:
Overall, I think the Silent Knight SD500-ANM is a great notification module. It is versatile, easy to install, and reliable. However, it is not the most affordable option on the market. If you are looking for a reliable and affordable notification module, the SD500-ANM is a great option. However, if you are on a tight budget, there may be other options that are more affordable.
Here are some additional thoughts on the SD500-ANM:
- The SD500-ANM is a good choice for applications where you need to add notification circuits to a remote location. The module can be powered from a separate power supply, so you do not have to worry about running long wires to the fire alarm control panel.
- The SD500-ANM is compatible with a variety of notification devices, including horns, strobes, and voice evacuation systems. This makes it a versatile device that can be used in a wide variety of applications.
- The SD500-ANM is UL listed and complies with NFPA 72. This means that the module has been tested and certified to meet the safety standards for fire alarm systems.
If you are considering the SD500-ANM, I recommend that you read the product reviews carefully. This will help you to get a better idea of the pros and cons of the module. I also recommend that you consult with a qualified fire alarm installer to ensure that the module is installed properly.
Silent Knight SD500-ANM Where To Buy
the places where you can buy Silent Knight SD500-ANM and spare parts:
- Direct: You can buy the Silent Knight SD500-ANM directly from the manufacturer's website. They have a wide variety of spare parts available as well.

- Walmart: Walmart carries a limited selection of Silent Knight products, including the SD500-ANM. You may be able to find spare parts here as well.

- Amazon: Amazon is a great place to find a wide variety of Silent Knight products, including the SD500-ANM and spare parts.

- Best Buy: Best Buy carries a limited selection of Silent Knight products, including the SD500-ANM. You may be able to find spare parts here as well.

- Lowes: Lowes carries a limited selection of Silent Knight products, including the SD500-ANM. You may be able to find spare parts here as well.

- eBay: eBay is a great place to find used or discontinued Silent Knight products, including the SD500-ANM and spare parts.

I hope this helps!
Silent Knight SD500-ANM Problems and Solutions
some common issues and problems with the Silent Knight SD500-ANM alarm panel, as well as solutions from experts:
- The panel is not powering on.
- Check the power supply to make sure it is plugged in and turned on.
- If the power supply is good, check the fuse on the panel.
- If the fuse is good, the panel may be defective and will need to be replaced.
- The panel is not receiving signals from the sensors.
- Check the wiring to the sensors to make sure it is secure and not damaged.
- If the wiring is good, check the batteries in the sensors to make sure they are not dead.
- If the batteries are good, the sensors may be defective and will need to be replaced.
- The panel is not sounding the alarm.
- Check the settings on the panel to make sure the alarm is enabled.
- If the alarm is enabled, check the sounder to make sure it is working properly.
- If the sounder is working properly, the panel may be defective and will need to be replaced.
Here are some additional tips for troubleshooting Silent Knight SD500-ANM alarm panels:
- Check the documentation. The documentation that came with your alarm panel will often have troubleshooting tips that can help you solve common problems.
- Contact the manufacturer. If you are unable to troubleshoot the problem yourself, you can contact the manufacturer of your alarm panel for assistance. They may be able to provide you with additional troubleshooting tips or send a technician to your home to fix the problem.
I hope this helps!
Silent Knight SD500-ANM Manual
Silent Knight SD500-ANM Manual
Safety Information
- This device must be installed and used in accordance with all applicable electrical and fire codes.
- Do not install this device in an area that is exposed to moisture or extreme temperatures.
- Do not attempt to service this device yourself. If the device is not functioning properly, contact a qualified technician.
Before Use
- Read and understand this manual before installing or using the SD500-ANM.
- Make sure that the device is properly installed and that all wiring is in accordance with the electrical code.
- Test the device to make sure that it is working properly.
Troubleshooting
If the SD500-ANM is not working properly, check the following:
- Is the device properly wired?
- Is the device getting power?
- Are there any tripped breakers or fuses?
- Is the device in alarm?
If you have checked all of these things and the device is still not working properly, contact a qualified technician.
Maintenance
The SD500-ANM requires very little maintenance. However, you should inspect the device periodically for signs of damage or wear. If you see any damage, contact a qualified technician.
Warranty
The SD500-ANM is covered by a one-year warranty. If the device fails within one year of purchase, it will be repaired or replaced free of charge.
Contact Information
Silent Knight 1000 Brookside Drive Maple Grove, MN 55369 Phone: 763-493-6455 Email: [email protected] Website: www.silentknight.com
Additional Information
- The SD500-ANM is an addressable notification module that can be used with Silent Knight IntelliKnight fire alarm control panels.
- The module provides one reverse polarity supervised notification appliance circuit.
- The notification circuit can be configured in either Class A (Style Z) or Class B (Style Y).
- The module is UL, CSFM, MEA 429-92-E, and FM approved.
I hope this manual has been helpful. If you have any further questions, please do not hesitate to contact us.